Part | Qty | |
---|---|---|
Laser cable | 1 | |
FAN cable | 1 | |
Power cable | 1 | |
cable tie catch | 10 | |
M3 post-in nut | 10 | |
M3×6 hex socket head cap bolt | 10 | |
cable tie | 10 |
Attach cable tie catch at position shown in the picture using M3 post-in nut and M3x6 hex socket head cap bolt.
Put AC-DC cable which was wired in Terminal block through the under washer socket like the picture.
Connect it to the switching power.
Connect the laser tube and laser power.
Lay the AC line and water cooling hose using cable tie catch attached earlier.
(*Use more cable tie catch as needed. There are extra cable ties and cable tie catches included.)
Connect laser cable to laser power.
Connect FAN cable (has two ends on both sides, white/black and red/green) to LED DC fan and water cooling pump.
(*either of two connectors of FAN cable can be connected to either of LED DC fan or water cooling pump. The shape of connectors are the same.)
Lay DC line cable using cable tie catch attached earlier.
(*Use more cable tie catch as needed. There are extra cable ties and cable tie catches included.)
Connect water-resistant polyurethane tube to touch panel connector.
Refer to the picture below and do the wiring of ten kinds of cables.
[X-Motor cable]
[Y-Motor-L cable]
[Y-Motor-R cable]
[FAN cable]
(*Use either of the two ends.)
[DC fan for radiator]
(*Use either of the two ends.)
[Flow monitor]
[Laser cable]
[Y1-Limit cable]
[Switch cable]
[Power cable]
[Pointer cable] (<== option: only for users who purchased positioning kit.)
Connect panel mount USB cable to control board.
This is the end of wiring.