FABOOL Laser CO2(2019~) Manual

Tester Conduction Confirmation

No. Parts Name Notes Pictures Qty
137 Tester   1
Battery   1

Assembly Procedure

Preparations for Tester Usage

Take the [137] Tester out of the package.

25-01.jpg

Remove the battery cover screw with a phillips head screwdriver.

25-02.jpg

Pull out the battery cable.

25-03.jpg

Connect the battery cable to the battery.

25-04.jpg

Insert the connected battery.

25-05.jpg

Close the battery cover and retighten the screw with a phillips head screwdriver.

25-06.jpg

Connect the test pins to the [137] Tester. The black one into “COM”, and the red one into “VΩmA”.

25-07.jpg

Turn the center dial from the original position to the “”buzzer”” position (circled in red in the photo).

25-08.jpg

Try touching the tips of the test pins together to make sure the buzzer sounds.

25-09.jpg

Conduction Confirmation: Terminal Black · Radiator Unit

Referring to the picture, touch the test pins to the ground wires of the [82] Ground(S) Cable and [20] Radiator Unit. Conduction is confirmed when the buzzer sounds.

* In case the buzzer doesn’t sound, there is the possibility that screws need to be tightened or the wiring is wrong. Try the tester again after tightening the screws firmly and re-checking the wiring.

25-10.jpg 25-11.jpg

Conduction Confirmation: Radiator Unit · AC-Main Cable

Check conduction by touching the test pin to the ground wire of the [20] Radiator Unit and the ground prong of the [63] AC-Main Cable power socket.

25-12.jpg 25-13.jpg

Conduction Confirmation: AC-Laser Cable · AC-Main Cable

Check conduction by touching the test pin to the black wire (marked FG) of the [62] AC-Laser Cable and the ground prong of the [63] AC-Main Cable power socket.

25-14.jpg 25-15.jpg