FABOOL Laser DS (2018/08~) Manual

Optical Axis Adjustment 2nd / 3rd Mirror

No. Parts Name Notes Pictures Qty
42 Reflecting Mirror Φ25mm 2
39 Focus Lens Φ20mm 1

Assembly Procedure

2nd Reflecting Mirror Adjustment

Attach 2nd Reflecting Mirror on the mirror mount.

34-1.jpg

Irradiate toward 3rd Reflecting Mirror.

Try from the close distance likewise the procedure of irradiation toward 2nd mirror mount.

34-2.jpg

Next, move the x-axis unit to the center of processing area.

34-3.jpg

Adjust 2nd mirror mount depending on the divergence occured. If the mirror mount is deviated greatly, adjust the 2nd mirror mount by turning the alminum frame itself gradually as it shown in the picture. Slight adjustment can be done by fixing the adjustment screw on the mirror mount.Try irradiation in short and long distance and correct the divergence one by one.

34-4.jpg

If the mirror mount is deviated greatly toward side direction, adjust it by turning the 2nd mirror mount gradually as it shown in the picture.

34-5.jpg

Slight adjustment can be done by fixing the adjustment screw on the mirror mount. Try irradiation in short and long distance and correct the divergence one by one.

34-6.jpg

After the adjustment, make sure that 2nd mirror mount can irradiate the center of the 3rd reflecting mirror.

3rd Reflecting Mirror Adjustment

34-7.jpg

Attach 3rd Reflecting Mirror on the mirror mount.

34-8.jpg

Slight adjustment can be done by fixing the adjustment screw on the mirror mount. After the adjustment, make sure that 3rd mirror mount can irradiate the center of the laser head.

34-9.jpg 34-10.jpg 34-11.jpg

Irradiate in every corner of the processing area and make sure that 3rd mirror mount can irradiate the center of the laser head.

Leftt Front34-13.jpg

Right Front34-14.jpg

Left Back34-15.jpg

Right Back34-16.jpg

Focus Lens Installation

Attach [39]Focus Lens on the mirror mount.*Make sure that the [39]Focus Lens is facing the right direction. The swollen side is the upper part.

34-17.jpg

Attach [39] Focus Lens, and the optical axis adjustment procedure is now completed.

34-18.jpg