Attach the fan to the radiator.
Please use the m3x28 hex socket cap bolts and M3 washers.
Attach the hose coupler fitting to the radiator.
Attach the right cover to the radiator. Be careful of the orientation, see picture below for reference.
Attach the rubber stand to the water cooling pump with the self tapping screws.
Attach the rubber feet, water cooling pump, electrical wiring board. Use the appropriate screws for each object as follows:
Insert the right and left covers into the bottom cover. Be careful of the orientation, See pictures for reference.
Insert the back cover, be careful of the orientation.
Insert the front cover, be careful of the orientation.
Please fix in place using the M5 × 20 hexagon socket head bolts and M5 nuts.
Repeat this on the opposite side also using the M5 × 20 hexagon socket head bolts and M5 nuts.
Using the picture below for reference, fix the brass spacers in place using the M5 × 20 hexagon socket head bolts.
Please cut the hose to suit your working environment
Cut off 200mm of hose and attach as shown in the picture below.
Attach one section of hose to the cooling pump OUT.
The other end will be attached to the laser tube IN.
Attach another section of hose to the radiator IN.
The other end will attach to laser tube OUT.
Please fix in place for the section of hose part.
Attach the hose from cooling pump OUT into the laser tube IN.
Fix in place with the cable tie.
The laser tube is made of glass so be careful not to damage it by tightening it too much
Attach the tube from radiator IN to laser tube OUT. (#1 reflecting mirror side)
Fix in place with the cable tie.
The laser tube is made of glass so be careful not to damage it by tightening it too much
Attach the flow meter to the radiator IN hose.
After all the hoses have been connected to the unit, run the pump while adding water.