FABOOL Laser CO2 Manual
Attach #2 reflection mirror to mirror mount.
Radiate toward #3 reflection mirror.
Similar to the #2 mirror, start from the closest point.
Radiate in the center of X-axis.
Adjust the #2 mirror mount according to the deviation.
If it deviates greatly to the vertical direction, adjust by turning the aluminum frame that i fixing the 2 mirror mount.
Make slight adjustments with adjustment screws on the mirror mount.
Make the deviation as small as possible when radiating from both close and far points.
If it is deviating greatly in horizontal direction, turn the #2 mirror mount little by little to make adjustments.
*The picture below is capturing the mirror mount from above.
Make slight adjustments with adjustment screws on mirror mount.
After adjustment, check that it radiates in the center of #3 reflection mirror.
Attach #3 reflection mirror.
Radiate to the laser head part.
If it deviates greatly in the horizontal direction (in the picture), adjust tilt of mirror mount of #3 reflection mirror.
Make slight adjustments with adjustment screws on mirror mount.
Adjust the screws on mirror mount so that the laser radiates to the center when radiation toward laser head part.
Check that laser is radiated in the center in all four corners of cutting area.
Attach condenser lens.
Watch for the orientation of it. The convex side is up.