FABOOL Laser CO2(2019~) Manual

Water Cooling Hose Installation (Laser Tube with Laser Pointer)

For laser tube without laser pointer click here.

No. Parts Name Notes Pictures Qty
26 Water Cooling Hose   1
61 Flow Sensor   1
38 Cable Ties   8

Assembly Procedure

Water-Cooling Hose Attachment

Attach hose to water-cooling pump outlet (shown in center).

Attach the hose from the water-cooling pump outlet to the non-radiating side of the laser tube (LED DC fan side).

Attach hose to inlet side (shown closest to viewer in picture) of water-cooling pump.

Attach hose from the water-cooling pump inlet to radiator unit shown closest to viewer in picture. Cut hose to appropriate length when attaching.

Attach hose to radiation side of laser tube (mirror 1 side).

*Do not apply excessive force as laser tube may shatter.

Attach to flow center. Cut hose to appropriate length when attaching.

*Attach so that the flow center indicated by the red arrow is facing the radiator side.

Attach the hose to the bottom of the flow center, and then to the radiator unit shown on the far side of the picture. Cut hose to appropriate length when attaching.

Fasten all eight hose attachment points using cable ties. Cut off the excess part of the cable ties.

Faster the hose attached from the water-cooling pump to the radiator to the AC Main cable with three cable ties.

*As shown in the picture, fasten the hose near the cable tie clamps that hold the AC Main cable.

Top